Local exhaust ventilation (LEV) is an engineering control system that captures airborne contaminants such as dust, fumes, mists, gases and vapors at or near the point where they are generated, then removes them from the workplace. By catching contaminants at the source, LEV keeps them out of workers' breathing zones.
LEV is generally more effective than general (dilution) ventilation for toxic substances, because dilution simply mixes contaminated air with clean air rather than removing the contaminant at the source.
Main Components of an LEV System
- Hood: where the contaminant enters the system. Hoods can be enclosing, capturing or receiving.
- Ductwork: carries the contaminated air away from the source.
- Air cleaner: removes contaminants before air is discharged, such as a dust collector, filter or scrubber.
- Fan: moves air through the system.
- Discharge stack: releases cleaned air outdoors, away from air intakes.
Types of Hoods
- Enclosing hoods, such as glove boxes and spray booths, surround the source and are the most effective.
- Capturing hoods, such as slot hoods and flexible arms, pull contaminants into the hood from outside it. They depend heavily on distance from the source.
- Receiving hoods, such as canopy hoods over hot processes, use the contaminant's own motion.
- Laboratory fume hoods are a common enclosing design used under a chemical hygiene plan.
OSHA Requirements
OSHA's ventilation standard, 29 CFR 1910.94, covers abrasive blasting, grinding and polishing, and spray finishing operations. Substance-specific standards, such as those for respirable crystalline silica, lead and hexavalent chromium, require engineering controls such as LEV where feasible. Under the hierarchy of controls, LEV is preferred over respirators.
Testing and Maintenance
LEV performance can drop due to damaged ducts, clogged filters, worn fans or changes to the system. Good practice includes:
- Measuring capture velocity, face velocity or static pressure at commissioning.
- Routine visual checks and airflow indicators at hoods.
- Periodic performance testing, often annually, by a competent person.
- Retesting after modifications to the system or process.
Common Mistakes to Avoid
- Placing capture hoods too far from the source.
- Adding branches to an existing system without rebalancing it.
- Ignoring filter changes and dust collector maintenance.
- Discharging exhaust near building air intakes.
- Not training workers on correct hood position.
How SMS360 Helps
SMS360's Risk Assessment module records LEV as a control for specific exposures. Audit Management schedules and records LEV inspections and airflow tests, and Actions Management assigns repairs when performance drops.
Frequently Asked Questions
What is the difference between LEV and general ventilation?
LEV captures contaminants at the source. General ventilation dilutes contaminants by bringing in fresh air across a whole area.
How often should LEV be tested?
Many organizations test LEV performance at least annually, with more frequent checks for high-hazard processes, and after any modification.
Is a fume hood a type of LEV?
Yes. A laboratory fume hood is an enclosing type of local exhaust ventilation.