A chemical hygiene plan (CHP) is a written program that sets out the procedures, equipment, personal protective equipment and work practices a laboratory uses to protect employees from health hazards of chemicals. It is the core requirement of OSHA's Occupational Exposure to Hazardous Chemicals in Laboratories standard, 29 CFR 1910.1450, often called the Laboratory Standard.
The CHP replaces many of the general industry chemical standards for laboratories that meet the standard's definition, so it must be specific to the lab and actually used, not just filed away.
Who Needs a Chemical Hygiene Plan?
Employers engaged in the laboratory use of hazardous chemicals must have a CHP. Laboratory use means chemical manipulations carried out on a laboratory scale, where multiple chemicals or procedures are used, the procedures are not part of a production process and protective laboratory practices and equipment are available. Research, academic, clinical and quality control labs often fall under this definition. Pilot plants and production-like processes generally do not.
Required Elements of a CHP
Under 1910.1450(e), the plan must include:
- Standard operating procedures for safety and health when working with hazardous chemicals.
- Criteria for control measures, such as engineering controls, PPE and hygiene practices.
- Fume hood and protective equipment performance requirements and checks.
- Information and training provisions for employees.
- Prior approval requirements for specific operations or procedures.
- Medical consultation and examination provisions.
- Designation of a Chemical Hygiene Officer and, where appropriate, a chemical hygiene committee.
- Additional protections for particularly hazardous substances, including select carcinogens, reproductive toxins and substances with high acute toxicity. These include designated areas, containment devices, safe waste removal and decontamination.
Training and Review
Employees must receive training at initial assignment and before assignments involving new exposure situations. Training covers the contents of the standard, the location of the CHP, exposure limits, signs and symptoms of exposure, location of reference material such as Safety Data Sheets, and methods to detect releases. The employer must review and evaluate the CHP at least annually and update it as needed.
Common Mistakes to Avoid
- Using a generic template that does not reflect actual lab hazards.
- Not designating particularly hazardous substances or their designated areas.
- Skipping annual fume hood checks or CHP reviews.
- Failing to offer medical consultation after a spill or exposure symptoms.
- Keeping the CHP somewhere employees cannot easily access.
How SMS360 Helps
SMS360's Document Library stores the current CHP and lab SOPs with version control and review reminders. Training Management assigns lab safety training and records completions, Safety Data Sheets keep chemical information accessible, and Audit Management supports routine fume hood and lab inspections.
Frequently Asked Questions
How often must a chemical hygiene plan be reviewed?
OSHA requires the employer to review and evaluate the effectiveness of the CHP at least annually and update it as necessary.
Who is the Chemical Hygiene Officer?
The Chemical Hygiene Officer is an employee designated by the employer who is qualified by training or experience to provide technical guidance in developing and implementing the CHP.
Does the Lab Standard replace the Hazard Communication Standard?
For laboratories covered by 1910.1450, the Lab Standard applies instead of most HazCom requirements, but labs must still keep labels on incoming containers and maintain access to SDSs.