An energy-isolating device is a mechanical device that physically prevents the transmission or release of energy. It is the point where authorized employees apply locks and tags during lockout/tagout.
OSHA's Control of Hazardous Energy standard, 29 CFR 1910.147, defines energy-isolating devices and requires them to be identified in written energy control procedures.
Examples of Energy-Isolating Devices
- A manually operated electrical circuit breaker.
- A disconnect switch.
- A manually operated switch that disconnects conductors from all ungrounded supply conductors, where no pole can be operated independently.
- A line valve for liquids, gases or steam.
- A block, such as a mechanical block that prevents movement.
- Any similar device used to block or isolate energy.
What Is Not an Energy-Isolating Device
OSHA specifically states that push buttons, selector switches and other control circuit type devices are not energy-isolating devices. Emergency stop buttons, interlocks and PLC commands can fail or be overridden, so they cannot be used as the sole means of isolation during servicing.
Lockable Design Requirements
Under 1910.147(c)(2)(iii), whenever equipment is replaced, repaired, renovated or modified, or new machines are installed after January 2, 1990, energy-isolating devices must be designed to accept a lockout device. If a device cannot be locked, the employer may use tagout only if it demonstrates the tagout program gives full employee protection equivalent to lockout.
Using Energy-Isolating Devices Safely
- Identify all energy sources. Electrical, mechanical, hydraulic, pneumatic, chemical, thermal and gravity.
- Locate each isolation point. List them in the equipment-specific procedure, ideally with photos.
- Shut down the equipment. Use the normal stopping procedure.
- Operate the isolating device. Open the disconnect, close the valve or install the block.
- Apply locks and tags. Each authorized employee applies a personal lock.
- Release stored energy. Bleed pressure, block parts and discharge capacitors.
- Verify isolation. Try to start the equipment and test for zero energy to reach a zero energy state.
Common Mistakes to Avoid
- Using a control switch or E-stop as the isolation point.
- Missing secondary energy sources such as backup power or gravity.
- Failing to label isolation points clearly.
- Not verifying isolation after locks are applied.
How SMS360 Helps
SMS360's Lockout/Tagout software stores equipment-specific procedures with each energy-isolating device, location and photo. Workers can pull up procedures on a phone in the field, and periodic inspections required by 1910.147(c)(6) can be scheduled and recorded so nothing slips.
Frequently Asked Questions
Is an emergency stop button an energy-isolating device?
No. OSHA does not consider push buttons, selector switches or other control circuit devices to be energy-isolating devices.
Do all energy-isolating devices need to accept a lock?
Devices on equipment installed, replaced or significantly modified after January 2, 1990 must be capable of accepting a lockout device.
Should isolation points be labeled?
OSHA does not require labels in every case, but labeling each isolation point to match the written procedure is a widely recommended best practice.