A zero energy state is the condition of a machine or system in which all sources of hazardous energy have been isolated, all stored or residual energy has been released or restrained, and the isolation has been verified. It is the goal of every lockout/tagout procedure and must be reached before workers place any part of their body in a danger zone.
The term reflects a simple idea: equipment is only safe to service when it cannot move, energize, release pressure or otherwise cause harm, even unexpectedly.
OSHA Requirements
OSHA's Control of Hazardous Energy standard, 29 CFR 1910.147(d), requires that:
- After lockout or tagout devices are applied, all potentially hazardous stored or residual energy is relieved, disconnected, restrained or otherwise rendered safe.
- If there is a possibility of reaccumulation of stored energy, verification of isolation continues until servicing is complete.
- Before starting work, the authorized employee verifies that isolation and de-energization have been accomplished.
Types of Stored Energy to Release
- Electrical: capacitors and batteries.
- Mechanical: flywheels, springs and moving parts that can coast.
- Hydraulic: pressure in lines, cylinders and accumulators.
- Pneumatic: compressed air in lines and tanks.
- Gravity: raised parts, loads or components that can fall.
- Thermal: hot or cold surfaces and fluids.
- Chemical: process fluids that can release or react.
How to Verify a Zero Energy State
- Clear the area. Make sure everyone is clear of the equipment.
- Try to start the equipment. Use normal operating controls to confirm it will not start.
- Test for voltage. Use a properly rated meter that has been checked on a known live source.
- Check gauges. Confirm pressure gauges read zero and bleed valves are open.
- Block or support. Install blocks, pins or cribbing for gravity hazards.
- Return controls to off. After the try-out, return controls to the off or neutral position.
- Monitor. Recheck where energy could reaccumulate.
Common Mistakes to Avoid
- Skipping the try-out step.
- Assuming a de-energized motor means no stored energy remains.
- Not blocking raised components.
- Forgetting to return controls to off after testing.
- Using meters that are not rated or tested for the voltage.
How SMS360 Helps
SMS360's Lockout/Tagout software includes verification steps in each equipment-specific procedure, listing stored energy sources and how to release them. Workers can access procedures on mobile, and periodic inspections confirm that verification is actually performed in the field.
Frequently Asked Questions
What does zero energy state mean?
It means all energy sources are isolated, stored energy is released or restrained, and the isolation has been verified, so the equipment cannot cause harm during servicing.
Is pressing the start button part of verification?
Yes. A try-out using normal controls is a common verification step, followed by returning the controls to off.
What if stored energy can reaccumulate?
OSHA requires continued verification until servicing is complete or until the possibility of reaccumulation no longer exists.