OSHA's Slings standard, 29 CFR 1910.184, sets requirements for slings used with cranes, hoists and other material handling equipment to lift loads in general industry. It covers alloy steel chain, wire rope, metal mesh, natural and synthetic fiber rope, and synthetic web slings.
Sling failures can drop loads on workers and cause fatalities. The standard focuses on safe rigging practices, daily inspections by a competent person and removing damaged slings from service immediately.
What Is the Slings Standard?
Section 1910.184 is part of 29 CFR 1910 Subpart N, Materials Handling and Storage. It applies to slings used with other material handling equipment for hoisting in general industry. Construction rigging is covered by 29 CFR 1926.251, and many employers also follow the ASME B30.9 consensus standard for slings.
Who Must Comply?
Any general industry employer that uses slings to lift materials, including manufacturing, steel service centers, warehouses, utilities, shipyards and maintenance operations with overhead cranes or hoists.
Key Requirements
Safe operating practices
Under 1910.184(c), whenever slings are used:
- Damaged or defective slings must not be used.
- Slings must not be shortened with knots, bolts or other makeshift devices.
- Sling legs must not be kinked.
- Slings must not be loaded beyond their rated capacity.
- Slings used in a basket hitch must have the loads balanced to prevent slippage.
- Slings must be securely attached to their loads.
- Slings must be padded or protected from the sharp edges of their loads.
- Suspended loads must be kept clear of all obstructions.
- All employees must be kept clear of loads about to be lifted and of suspended loads.
- Hands or fingers must not be placed between the sling and its load while the sling is being tightened around the load.
- Shock loading is prohibited.
- A sling must not be pulled from under a load when the load is resting on the sling.
Daily inspections
Under 1910.184(d), each day before being used, the sling and all fastenings and attachments must be inspected for damage or defects by a competent person designated by the employer. Additional inspections must be performed during sling use where service conditions warrant. Damaged or defective slings must be immediately removed from service.
Alloy steel chain slings
- Must have permanently affixed durable identification stating size, grade, rated capacity and reach.
- Must receive a thorough periodic inspection, at intervals based on frequency of use, severity of service, nature of lifts and prior experience, but at least once every 12 months.
- The employer must keep a record of the most recent month in which each alloy steel chain sling was thoroughly inspected and make it available for examination.
- Slings must be removed from service when heat damage, excessive wear, stretch, cracked or deformed links or hooks are found.
Wire rope slings
Wire rope slings must be removed from service if there are:
- Ten randomly distributed broken wires in one rope lay, or five broken wires in one strand in one rope lay.
- Wear or scraping of one-third of the original diameter of outside individual wires.
- Kinking, crushing, bird caging or any other damage resulting in distortion of the rope structure.
- Evidence of heat damage.
- End attachments that are cracked, deformed or worn.
- Corrosion of the rope or end attachments.
Synthetic web slings
- Each sling must be marked or coded to show the rated capacities for each type of hitch and the type of synthetic web material.
- Nylon and polyester web slings must not be used at temperatures above 180°F, and polypropylene web slings above 200°F.
- Slings must be removed from service if there are acid or caustic burns, melting or charring, snags, punctures, tears or cuts, broken or worn stitches, or distortion of fittings.
Rated capacity
Slings must not be used above their rated capacity, which depends on the sling type, size, hitch and angle. As sling angles decrease from vertical, the tension in each leg increases, so angle must be considered in every lift.
Penalties and Enforcement
OSHA cites 1910.184 for damaged slings in use, missing identification tags, missing inspection records for alloy chain slings and unsafe rigging practices. Maximum penalties are $16,550 per serious violation and $165,514 per willful or repeat violation in 2026.
Common Compliance Mistakes
- Using slings with missing or illegible capacity tags.
- Skipping daily pre-use inspections.
- No record of annual alloy chain sling inspections.
- Ignoring sling angle when calculating load.
- No edge protection on sharp loads.
- Storing slings where they are exposed to chemicals, heat or sunlight.
How to Comply: Step by Step
- Inventory slings. Give each sling a unique ID and confirm it has a legible tag.
- Designate competent persons. Train them to inspect slings daily before use.
- Set removal criteria. Publish clear removal criteria for each sling type.
- Schedule periodic inspections. Inspect alloy chain slings at least every 12 months and keep records.
- Train riggers. Cover hitches, sling angles, capacity, edge protection and load control.
- Store properly. Hang slings off the floor, away from heat, chemicals and UV light.
- Destroy damaged slings. Cut or tag them so they cannot be reused.
How SMS360 Helps
SMS360's Audits & Inspections module supports daily and periodic sling inspections with photo evidence and records by sling ID. Training Management tracks rigger and competent person training, and Actions Management records removal and replacement of defective slings.
Frequently Asked Questions
How often must slings be inspected?
Every day before use by a competent person. Alloy steel chain slings also need a thorough periodic inspection at least every 12 months.
Do I need records of sling inspections?
OSHA requires a record of the most recent month each alloy steel chain sling was thoroughly inspected. Many employers keep records for all sling types as a best practice.
Can a damaged sling be repaired?
Only by the manufacturer or an equivalent entity, and repaired slings must be proof tested and marked before returning to service.
What temperature limits apply to web slings?
Nylon and polyester web slings must not be used above 180°F, and polypropylene web slings above 200°F.