EPA's Emergency Planning and Notification regulations, 40 CFR Part 355, implement Sections 302, 303 and 304 of the Emergency Planning and Community Right-to-Know Act (EPCRA). They require facilities that have extremely hazardous substances (EHSs) above certain amounts to participate in local emergency planning, and require facilities to report certain chemical releases to state and local authorities immediately.
Together with Tier II reporting and TRI reporting, these rules help communities prepare for and respond to chemical emergencies.
What Is 40 CFR Part 355?
Part 355 has two main parts:
- Subpart B, Emergency Planning: EPCRA Sections 302 and 303.
- Subpart C, Emergency Release Notification: EPCRA Section 304.
Appendices A and B list the EHSs and their threshold planning quantities (TPQs) and reportable quantities (RQs).
Who Must Comply?
- Emergency planning: any facility where an EHS is present at any one time in an amount equal to or greater than its TPQ.
- Release notification: any facility where a hazardous chemical is produced, used or stored, and where there is a release of an EHS or a CERCLA hazardous substance at or above its RQ in any 24-hour period.
Many manufacturing plants, water treatment facilities, cold storage warehouses using anhydrous ammonia, chemical distributors, farms and retailers can be covered.
Key Requirements
Emergency planning notification
Facilities with an EHS at or above its TPQ must notify the State Emergency Response Commission (SERC) and the Local Emergency Planning Committee (LEPC) within 60 days after first becoming subject. EHS amounts in mixtures must be counted when determining whether the TPQ is met.
Facility emergency coordinator
Covered facilities must designate a facility emergency coordinator to participate in the local emergency planning process and notify the LEPC of that person. Changes relevant to emergency planning, including a change in coordinator, must be reported to the LEPC within 30 days, and the facility must provide information the LEPC requests for developing and implementing the local emergency plan.
Immediate release notification
When a reportable release occurs that may affect people outside the facility, the owner or operator must immediately notify:
- The community emergency coordinator for the LEPC of any area likely to be affected.
- The SERC of any state likely to be affected.
Where there is no LEPC, notification goes to relevant local emergency response personnel. Releases of CERCLA hazardous substances must also be reported to the National Response Center under CERCLA release reporting.
The immediate notice must include, to the extent known:
- The chemical name or identity.
- Whether it is an EHS.
- An estimate of the quantity released.
- The time and duration of the release.
- The environmental medium, such as air, water or land.
- Known or anticipated acute or chronic health risks and, where appropriate, advice on medical attention.
- Proper precautions, such as evacuation or sheltering in place.
- The name and telephone number of a contact person.
Written follow-up
As soon as practicable after the release, the facility must provide written follow-up notice to the SERC and LEPC that updates the initial information and includes actions taken to respond to and contain the release, any known or anticipated health risks, and advice on medical attention for exposed individuals.
Exemptions
Some releases are exempt from Section 304 notification, including releases that result in exposure only to persons within the facility boundaries, federally permitted releases, and certain continuous releases, which follow reduced reporting procedures. Transportation-related releases have their own notification provisions.
Penalties and Enforcement
EPA enforces EPCRA through inspections and reviews of release reports, and late notification is a frequent violation, especially for ammonia and chlorine releases. Civil penalties are assessed per day per violation and are adjusted annually for inflation. Knowing and willful failure to report can bring criminal penalties.
Common Compliance Mistakes
- Not tracking EHS inventory against TPQs, especially in mixtures.
- Delaying notification while investigating the release.
- Calling only 911 or the National Response Center and not the SERC and LEPC.
- Missing written follow-up reports.
- Not updating the LEPC when the facility emergency coordinator changes.
How to Comply: Step by Step
- Inventory EHSs and compare quantities to TPQs.
- Notify the SERC and LEPC within 60 days of becoming subject.
- Designate a facility emergency coordinator and keep contact information current.
- Calculate RQs for chemicals you handle and know what release amounts trigger reporting.
- Write a release reporting procedure with phone numbers for the SERC, LEPC and NRC.
- Train responders and supervisors on immediate notification.
- Submit written follow-up after every reportable release.
How SMS360 Helps
SMS360's Incident Management module captures environmental releases with quantity, time, duration and notifications made. Safety Data Sheets help identify EHSs and quantities, the Document Library stores release reporting procedures and agency contacts, and Actions Management tracks written follow-ups and corrective actions.
Frequently Asked Questions
What is a threshold planning quantity?
The amount of an EHS that, when present at a facility at any one time, triggers emergency planning notification under EPCRA Section 302.
How quickly must a release be reported under EPCRA?
Immediately, to the LEPC community emergency coordinator and the SERC, followed by written notice as soon as practicable.
Do releases that stay inside the facility need to be reported?
EPCRA Section 304 does not apply to releases that result in exposure only to persons within the facility boundaries, but CERCLA reporting to the NRC may still apply.
Is EPCRA reporting the same as CERCLA reporting?
No. CERCLA requires reporting to the National Response Center. EPCRA requires reporting to state and local authorities. Many releases trigger both.