Resources
/
Regulations
/
EPCRA Emergency Planning and Release Notification
EPA

EPCRA Emergency Planning and Release Notification

EPCRA 40 CFR 355 explained: EHS threshold planning quantities, facility emergency coordinators, immediate release notices to SERCs and LEPCs.

40 CFR Part 355

Requires facilities with extremely hazardous substances to join emergency planning and to report releases above reportable quantities immediately.

EPA's Emergency Planning and Notification regulations, 40 CFR Part 355, implement Sections 302, 303 and 304 of the Emergency Planning and Community Right-to-Know Act (EPCRA). They require facilities that have extremely hazardous substances (EHSs) above certain amounts to participate in local emergency planning, and require facilities to report certain chemical releases to state and local authorities immediately.

Together with Tier II reporting and TRI reporting, these rules help communities prepare for and respond to chemical emergencies.

What Is 40 CFR Part 355?

Part 355 has two main parts:

  • Subpart B, Emergency Planning: EPCRA Sections 302 and 303.
  • Subpart C, Emergency Release Notification: EPCRA Section 304.

Appendices A and B list the EHSs and their threshold planning quantities (TPQs) and reportable quantities (RQs).

Who Must Comply?

  • Emergency planning: any facility where an EHS is present at any one time in an amount equal to or greater than its TPQ.
  • Release notification: any facility where a hazardous chemical is produced, used or stored, and where there is a release of an EHS or a CERCLA hazardous substance at or above its RQ in any 24-hour period.

Many manufacturing plants, water treatment facilities, cold storage warehouses using anhydrous ammonia, chemical distributors, farms and retailers can be covered.

Key Requirements

Emergency planning notification

Facilities with an EHS at or above its TPQ must notify the State Emergency Response Commission (SERC) and the Local Emergency Planning Committee (LEPC) within 60 days after first becoming subject. EHS amounts in mixtures must be counted when determining whether the TPQ is met.

Facility emergency coordinator

Covered facilities must designate a facility emergency coordinator to participate in the local emergency planning process and notify the LEPC of that person. Changes relevant to emergency planning, including a change in coordinator, must be reported to the LEPC within 30 days, and the facility must provide information the LEPC requests for developing and implementing the local emergency plan.

Immediate release notification

When a reportable release occurs that may affect people outside the facility, the owner or operator must immediately notify:

  • The community emergency coordinator for the LEPC of any area likely to be affected.
  • The SERC of any state likely to be affected.

Where there is no LEPC, notification goes to relevant local emergency response personnel. Releases of CERCLA hazardous substances must also be reported to the National Response Center under CERCLA release reporting.

The immediate notice must include, to the extent known:

  • The chemical name or identity.
  • Whether it is an EHS.
  • An estimate of the quantity released.
  • The time and duration of the release.
  • The environmental medium, such as air, water or land.
  • Known or anticipated acute or chronic health risks and, where appropriate, advice on medical attention.
  • Proper precautions, such as evacuation or sheltering in place.
  • The name and telephone number of a contact person.

Written follow-up

As soon as practicable after the release, the facility must provide written follow-up notice to the SERC and LEPC that updates the initial information and includes actions taken to respond to and contain the release, any known or anticipated health risks, and advice on medical attention for exposed individuals.

Exemptions

Some releases are exempt from Section 304 notification, including releases that result in exposure only to persons within the facility boundaries, federally permitted releases, and certain continuous releases, which follow reduced reporting procedures. Transportation-related releases have their own notification provisions.

Penalties and Enforcement

EPA enforces EPCRA through inspections and reviews of release reports, and late notification is a frequent violation, especially for ammonia and chlorine releases. Civil penalties are assessed per day per violation and are adjusted annually for inflation. Knowing and willful failure to report can bring criminal penalties.

Common Compliance Mistakes

  • Not tracking EHS inventory against TPQs, especially in mixtures.
  • Delaying notification while investigating the release.
  • Calling only 911 or the National Response Center and not the SERC and LEPC.
  • Missing written follow-up reports.
  • Not updating the LEPC when the facility emergency coordinator changes.

How to Comply: Step by Step

  1. Inventory EHSs and compare quantities to TPQs.
  2. Notify the SERC and LEPC within 60 days of becoming subject.
  3. Designate a facility emergency coordinator and keep contact information current.
  4. Calculate RQs for chemicals you handle and know what release amounts trigger reporting.
  5. Write a release reporting procedure with phone numbers for the SERC, LEPC and NRC.
  6. Train responders and supervisors on immediate notification.
  7. Submit written follow-up after every reportable release.

How SMS360 Helps

SMS360's Incident Management module captures environmental releases with quantity, time, duration and notifications made. Safety Data Sheets help identify EHSs and quantities, the Document Library stores release reporting procedures and agency contacts, and Actions Management tracks written follow-ups and corrective actions.

Frequently Asked Questions

What is a threshold planning quantity?

The amount of an EHS that, when present at a facility at any one time, triggers emergency planning notification under EPCRA Section 302.

How quickly must a release be reported under EPCRA?

Immediately, to the LEPC community emergency coordinator and the SERC, followed by written notice as soon as practicable.

Do releases that stay inside the facility need to be reported?

EPCRA Section 304 does not apply to releases that result in exposure only to persons within the facility boundaries, but CERCLA reporting to the NRC may still apply.

Is EPCRA reporting the same as CERCLA reporting?

No. CERCLA requires reporting to the National Response Center. EPCRA requires reporting to state and local authorities. Many releases trigger both.

Incident Management

See how SMS360 handles this

Keep the records, inspections, training and corrective actions this rule requires in one place, with dashboards that keep you audit-ready.

Request a Demo
Explore the module →

Related topics

Laptop, smartphone, and tablet displaying SMS360 Demo Site with dashboards and incident reporting interfaces.
Free product demo

See how SMS360 simplifies safety, compliance, and reporting — all in one easy-to-use platform.

Get a personalized walkthrough of the platform, built around your team's workflows.

Explore the Core Modules That Power SMS360

Unite your entire safety program — incidents, audits, training, and compliance — in one place.

Audits & Inspections
Simplify every audit and inspection and stay compliant-ready year-round.
Conduct inspections on desktop, tablet, or mobile — even offline.
Customize checklists for departments, sites, or equipment.
Instantly flag and assign corrective actions to stay compliant.
Learn More
Incident Management
Take control of incidents from first response to resolution — all in one place.
Automate OSHA and DOT reporting with digital incident logs.
Capture photos, witness statements, and root causes in seconds.
Track corrective actions to close out incidents faster and prevent repeats.
Learn More
Regulatory Compliance
Keep your facility compliant with OSHA, DOT, and EPA — without the paperwork.
Manage permits, notices of violation, and inspection history.
Stay ahead of deadlines with automatic reminders and alerts.
Generate compliance reports in seconds for internal or external audits.
Learn More
Safety Observations
Identify risks before they become incidents — empower teams to act on the spot.
Log unsafe conditions or behaviors from any device.
Track trends by site, department, or supervisor.
Close the loop with automatic follow-ups and status tracking.
Learn More
Training Management
Build safer, smarter teams with consistent, trackable employee training and tracking management software.
Automate reminders, track sessions, and ensure timely completion.
Centralize attendance, upload documents, and maintain records.
Manage classroom and on-the-job training from a single platform.
Learn More
Risk Assessment
Turn environmental, health, and safety data into insight — predict and prevent what’s next.
Analyze trends and exposure using customizable risk models.
Rank hazards by severity and likelihood for smarter prevention.
Export visual risk reports for leadership and safety committees.
Learn More
Fleet Management
Manage drivers, vehicles, and inspections with Fleet360, software for fleet management.
Track driver qualifications, vehicle history, and DVIR logs.
Automate maintenance scheduling and compliance checks.
Stay FMCSA-ready with digital records and reports.
Learn More
Claims Management
Simplify the claims management process and get visibility into every cost and outcome.
Track claim expenses, statuses, and resolutions in real time.
Attach documentation, reports, and correspondence securely.
Reduce claim turnaround times with automated follow-up workflows.
Learn More
Work Permits
Digitize your permit process to ensure every task is reviewed, approved, and performed safely.
Create, review, and approve permits for high-risk work in minutes.
Assign responsible personnel and verify authorizations before tasks begin.
Track active, pending, and expired permits in real time.
Learn More
Lockout Tagout (LOTO)
Ensure equipment is safely locked and tagged before maintenance starts with SMS360's lockout tagout software.
Digitize and verify lockout/tagout procedures per asset.
Track authorization and completion for every employee.
Reduce equipment-related injuries and OSHA violations.
Learn More
Safety Data Sheets
Keep all chemical safety data accessible and compliant in one, easy-to-use SDS management system.
Store, search, and update SDS records anytime.
Provide instant access to workers during emergencies.
Ensure regulatory compliance with centralized documentation.
Learn More
Management of Change
Control how organizational, process, or equipment changes are requested, reviewed, and approved.
Submit and track change requests with clear status updates.
Assign reviewers and document risk or cost impacts instantly.
Maintain an auditable record of approvals and dispositions.
Learn More
Actions Management
Assign corrective and preventative  actions, set priorities, and monitor your team's progress to ensure nothing slips through the cracks.
Create, assign, and monitor actions with real-time updates.
Prioritize actions by risk level and due date.
Attach documents and notes for a complete audit trail.
Learn More
Document Library
Keep every safety and compliance file in one secure place. Upload, organize, and share documents instantly with full version control.
Store SDSs, manuals, and training files in one hub.
Add quick links to OSHA and external resources.
Manage permissions to control file access.
Learn More
Analytics & Reports
Generate reports, track KPIs, and uncover trends to improve environmental, health, and safety performance.
Instantly create OSHA, KPI, and incident reports.
Spot trends with causal analysis tools in SMS360.
Schedule and share safety and fleet reports.
Learn More