OSHA's Cadmium standard, 29 CFR 1910.1027, protects workers from exposure to cadmium and its compounds. Cadmium is a toxic metal that can cause kidney damage, lung damage, bone disease and lung cancer. It is classified as a known human carcinogen.
Because cadmium accumulates in the body over time, the standard includes biological monitoring and medical removal protection in addition to air exposure limits.
What Is the Cadmium Standard?
Section 1910.1027 is part of 29 CFR 1910 Subpart Z, Toxic and Hazardous Substances. A parallel standard, 29 CFR 1926.1127, covers construction work.
Who Must Comply?
The standard applies to all occupational exposures to cadmium and cadmium compounds in all forms. Common sources include:
- Nickel-cadmium battery manufacturing and recycling.
- Electroplating and metal coatings.
- Cadmium pigments in plastics, ceramics and glass.
- Zinc, lead and copper smelting and refining.
- Welding, cutting, brazing and soldering on cadmium-containing materials.
- Some solar panel and electronics manufacturing.
- Demolition and removal of cadmium-containing coatings in construction.
Key Requirements
Exposure limits
- Permissible exposure limit (PEL): 5 micrograms per cubic meter of air (5 µg/m³) as an 8-hour time-weighted average.
- Action level: 2.5 µg/m³ as an 8-hour TWA.
Exposure monitoring
Employers must determine whether any employee may be exposed at or above the action level. If so, initial monitoring is required, and periodic monitoring must be repeated at least every 6 months while exposures remain at or above the action level. Monitoring must also be repeated when changes could result in new or additional exposures. Employees must be notified of results.
Regulated areas
Areas where exposures exceed or can reasonably be expected to exceed the PEL must be established as regulated areas, demarcated and posted with warning signs. Eating, drinking, smoking, chewing gum or tobacco and applying cosmetics are prohibited in regulated areas.
Methods of compliance
Employers must use engineering and work practice controls to reduce exposures to or below the PEL, except where infeasible. Where exposures exceed the PEL, a written compliance program must be developed and updated at least annually. Respirators are used when controls are insufficient.
Protective clothing and hygiene
Where exposure is above the PEL or skin and eye irritation is possible, employers must provide protective clothing and equipment at no cost, along with change rooms, showers, lunchrooms with clean air and handwashing facilities. Contaminated clothing must be removed and stored in labeled containers.
Medical surveillance
Medical surveillance is required for employees who are or may be exposed at or above the action level for 30 or more days per year, and for some previously exposed employees. It includes a medical and work history, physical exam and biological monitoring.
Biological monitoring
Biological monitoring measures:
- Cadmium in urine (CdU).
- Beta-2-microglobulin in urine (β2-M), a marker of kidney damage.
- Cadmium in blood (CdB).
Results above levels set in the standard require more frequent monitoring, a review of controls and work practices, and in some cases medical removal.
Medical removal protection
Employees removed from exposure because of biological monitoring results or a physician's determination must receive medical removal protection benefits, including earnings, seniority and other rights, for up to 18 months.
Training and recordkeeping
Employees exposed at or above the action level must receive training before or at the time of initial assignment and at least annually. Exposure records must be kept for at least 30 years, and medical records for the duration of employment plus 30 years.
Penalties and Enforcement
Common violations include missing exposure monitoring, missing medical surveillance, inadequate hygiene facilities and eating in regulated areas. Maximum penalties are $16,550 per serious violation and $165,514 per willful or repeat violation in 2026.
Common Compliance Mistakes
- Overlooking cadmium in coatings during welding, cutting or grinding.
- Not offering medical surveillance to former exposed employees where required.
- Allowing food and drink in or near regulated areas.
- Taking contaminated work clothing home.
- Missing annual updates to the written compliance program.
How to Comply: Step by Step
- Identify sources. Review SDSs, coatings and processes for cadmium.
- Monitor exposures. Sample representative employees for 8-hour TWAs.
- Set up regulated areas where the PEL may be exceeded.
- Control exposures. Use ventilation, enclosure, substitution and wet methods.
- Write a compliance program and update it annually.
- Provide hygiene facilities. Supply change rooms, showers and clean eating areas.
- Start medical surveillance with biological monitoring for eligible employees.
- Train annually and keep records for 30 years.
How SMS360 Helps
SMS360's Risk Assessment module documents cadmium exposure assessments and controls. Safety Data Sheets identify cadmium-containing products, Training Management tracks annual training and medical surveillance schedules, and the Document Library supports long-term retention of exposure and medical records.
Frequently Asked Questions
What is the OSHA PEL for cadmium?
5 µg/m³ as an 8-hour TWA, with an action level of 2.5 µg/m³.
Who needs cadmium medical surveillance?
Employees exposed at or above the action level for 30 or more days per year, and certain previously exposed employees.
What biological tests are used for cadmium?
Cadmium in urine, beta-2-microglobulin in urine and cadmium in blood.
How long does cadmium medical removal protection last?
Up to 18 months of maintained earnings, seniority and benefits.