OSHA's Accident Prevention Signs and Tags standard, 29 CFR 1910.145, sets requirements for the design, application and use of signs, symbols and tags that warn workers of hazards. It defines when to use danger, caution and safety instruction signs, which colors they must use, and how accident prevention tags must be designed and attached.
Signs and tags are among the simplest safety controls, but they only work when they are consistent, readable and used for real hazards. Overused or inconsistent signage teaches people to ignore warnings.
What Is the Accident Prevention Signs and Tags Standard?
Section 1910.145 is part of 29 CFR 1910 Subpart J, General Environmental Controls. It covers signs and symbols intended to indicate and, as far as possible, define specific hazards that could cause injury or property damage. It does not cover plant bulletin boards or safety posters.
The standard works alongside other OSHA rules that require specific signs, such as the lockout/tagout, bloodborne pathogens, confined space and hazard communication standards.
Who Must Comply?
All general industry employers that use signs or tags to warn of hazards must follow 1910.145. Construction employers follow similar rules in 29 CFR 1926.200, and maritime employers have their own provisions.
Key Requirements
Sign classifications
- Danger signs: used only where an immediate hazard exists. Employees must be instructed that danger signs indicate immediate danger and that special precautions are necessary.
- Caution signs: used to warn against potential hazards or to caution against unsafe practices. Employees must be instructed that caution signs indicate a possible hazard.
- Safety instruction signs: used where there is a need for general instructions and suggestions relative to safety measures.
- Biological hazard signs: used to signify the actual or potential presence of a biohazard and to identify equipment, containers, rooms and materials that contain or are contaminated with infectious agents.
Colors
- Danger signs: red, or predominantly red, with lettering or symbols in a contrasting color.
- Caution signs: yellow background with a black panel and yellow letters, with black lettering on the yellow background below the panel.
- Safety instruction signs: white background with a green panel and white letters, with black lettering on the white background below the panel.
- Biological hazard signs: fluorescent orange or orange-red, or predominantly so, with lettering or symbols in a contrasting color.
ANSI Z535 alternatives
OSHA updated its sign and tag standards in 2013 so employers may use signs and tags designed to the 2011 editions of ANSI Z535.1, Z535.2 and Z535.5, in addition to the older ANSI Z35 designs the standard was originally based on. ANSI Z535 signs use the signal words DANGER, WARNING, CAUTION and NOTICE and encourage safety symbols and clear hazard statements.
Sign design and wording
Signs must have rounded or blunt corners and be free of sharp edges, burrs, splinters or other sharp projections. Ends or heads of bolts and fastening devices must be located so they do not create a hazard. Wording should be easy to read and concise, with enough information to be understood, and it should make a positive rather than negative suggestion where possible.
Accident prevention tags
Under 1910.145(f), tags must be used as a means to prevent accidental injury or illness to employees exposed to hazardous or potentially hazardous conditions, equipment or operations that are out of the ordinary, unexpected or not readily apparent. Tags must be used until the hazard is eliminated or the hazardous operation is completed. Key tag requirements:
- Each tag must contain a signal word and a major message.
- The signal word must be "Danger," "Caution" or "Biological Hazard," "BIOHAZARD" or the biological hazard symbol. "Warning" tags may be used where the hazard level is between caution and danger.
- The major message must indicate the specific hazardous condition or the instruction to be communicated.
- The signal word must be readable at a minimum distance of 5 feet or greater distance as warranted by the hazard.
- Tags and their attachments must be legible and durable for the expected conditions.
- Tags must be affixed as close as safely possible to their respective hazards by a positive means, such as string, wire or adhesive, that prevents their loss or unintentional removal.
- Employees must be informed of the meaning of the various tags used and the special precautions necessary.
Penalties and Enforcement
OSHA cites 1910.145 when signs or tags are missing, use the wrong signal word or colors, or are illegible. Missing signs are often cited together with the underlying hazard, such as an unmarked permit-required confined space. Maximum penalties are $16,550 per serious or other-than-serious violation and $165,514 per willful or repeat violation, the amounts in effect since January 2025 and unchanged for 2026.
Common Compliance Mistakes
- Using danger signs for minor hazards, which dilutes their meaning.
- Mixing old ANSI Z35 and newer Z535 designs inconsistently across a site.
- Faded, damaged or obstructed signs that cannot be read.
- Tags attached with tape that falls off or can be easily removed.
- Tags left in place long after the hazard has been corrected.
- Not training employees on what each sign and tag means.
How to Comply: Step by Step
- Inventory hazards. Walk the site and list hazards that need signs or tags.
- Choose a system. Select OSHA 1910.145 designs or ANSI Z535 designs and apply them consistently.
- Match signal words to risk. Use danger only for immediate hazards that could cause death or serious injury.
- Write clear messages. Name the hazard, the consequence and how to avoid it.
- Install correctly. Place signs where they will be seen before the hazard is encountered, at a readable height and distance.
- Control tags. Set rules for who may place and remove tags and how they are attached.
- Train employees. Explain the meaning of each sign and tag type.
- Inspect regularly. Replace damaged, faded or outdated signs and remove obsolete tags.
How SMS360 Helps
SMS360's Audits & Inspections module adds signage checks to facility inspections, with photos of missing or damaged signs. Safety Observations let employees report signage problems instantly, Actions Management tracks replacements, and Training Management records hazard recognition training.
Frequently Asked Questions
What is the difference between a danger sign and a caution sign?
Danger signs are for immediate hazards where special precautions are necessary. Caution signs warn of potential hazards or unsafe practices.
Can employers use ANSI Z535 signs instead of OSHA designs?
Yes. Since 2013, OSHA allows signs and tags that meet the 2011 editions of ANSI Z535.1, Z535.2 and Z535.5.
How far away must a tag's signal word be readable?
At least 5 feet, or a greater distance if the hazard warrants it.
Are "Warning" tags allowed?
Yes. OSHA allows warning tags where a hazard level falls between caution and danger.