An assigned protection factor (APF) is the workplace level of respiratory protection that a respirator, or class of respirators, is expected to provide when it is functioning properly and worn by trained, fit-tested employees. An APF of 10 means the respirator should reduce the concentration of a contaminant inside the facepiece to one-tenth of the concentration outside.
APFs are defined in OSHA's Respiratory Protection Standard at 29 CFR 1910.134(d)(3)(i)(A). Employers must use them when selecting respirators.
OSHA's APF Table
Common values from OSHA's Table 1 include:
- Filtering facepiece or half-mask air-purifying respirator: 10
- Full-facepiece air-purifying respirator: 50
- Half-mask powered air-purifying respirator (PAPR): 50
- Full-facepiece PAPR: 1,000
- Loose-fitting facepiece PAPR: 25
- Helmet or hood PAPR: 25, or 1,000 if the manufacturer has test evidence of that level of performance
- Full-facepiece supplied-air respirator in pressure-demand mode: 1,000
- Self-contained breathing apparatus (SCBA), full facepiece, pressure demand: 10,000
Substance-specific standards, such as those for asbestos, lead or silica, may set different respirator requirements, and those take precedence.
Maximum Use Concentration
The APF is used to calculate the maximum use concentration (MUC), the highest concentration of a contaminant in which a respirator can be used:
MUC = APF × exposure limit
For example, if a contaminant has a permissible exposure limit of 5 ppm, a half-mask APR with an APF of 10 has an MUC of 50 ppm. If measured exposures reach 120 ppm, a higher-protection respirator such as a full-facepiece APR (MUC 250 ppm) is needed. The MUC can never exceed the IDLH value or the cartridge's rated limits.
How to Use APFs in Respirator Selection
- Measure or estimate exposure. Use air monitoring or objective data for each task.
- Find the exposure limit. Use the OSHA PEL or a more protective occupational exposure limit if your program uses one.
- Calculate the required protection. Divide the exposure by the limit to get the minimum protection factor needed.
- Select a respirator. Choose a respirator class with an APF equal to or greater than that number.
- Check other factors. Confirm the contaminant form, oxygen level, eye irritation, comfort and work rate.
- Document the decision. Record the data and reasoning in your respiratory protection program.
Common Mistakes to Avoid
- Treating the APF as a guarantee for workers who are not fit tested or trained.
- Choosing respirators based on habit rather than exposure data.
- Ignoring substance-specific standards with stricter requirements.
- Forgetting to reassess when processes, materials or exposures change.
How SMS360 Helps
SMS360's Risk Assessment module documents exposure assessments, required protection levels and selected controls for each task. Linked Safety Data Sheets provide exposure limits, and Training Management tracks fit tests and respirator training so the APF assumptions in your program hold true in the field.
Frequently Asked Questions
What is the APF of an N95?
An N95 is a filtering facepiece respirator with an APF of 10 under OSHA's table.
What is the difference between an APF and a fit factor?
A fit factor is a measurement from a quantitative fit test on a specific person. An APF is a regulatory value assigned to a class of respirators for selection purposes.
Who sets assigned protection factors?
OSHA sets APFs in 29 CFR 1910.134. NIOSH certifies respirators but uses its own assigned protection factors in some guidance documents.